Today's win: you'll predict how MIG partitions a GPU, how it differs from
time-slicing, and which your cluster uses.
The setup
A 94 GB GPU running a model that needs only 20 GB wastes most of itself. You want several workloads to
share one physical GPU.
Step 1: what MIG does
Step 2: MIG vs time-slicing
Recall (cover the screen): MIG vs time-slicing, one line each. MIG = hardware partition into isolated instances (own SMs/HBM/L2): guaranteed, no noisy neighbor, but rigid. Time-slicing = tenants share the whole GPU in turns: flexible and oversubscribable, but no isolation (a heavy tenant starves others).(tap/hover to check)
Step 3: when to use which
Step 4: your cluster (real)
On YOUR cluster real config
You run time-slicing ×5 → 20 logical GPUs, MIG disabled: flexible/oversubscribed,
but no hardware isolation (noisy-neighbor risk to SLOs). Your 27B Qwen wants a whole GPU regardless.
MIG would be the switch if you needed guaranteed per-tenant isolation. Your Lab →
Explain to a colleague: "We'd switch from time-slicing to MIG if…" …we needed guaranteed per-tenant isolation. MIG gives each instance its own SMs/HBM in hardware, so no noisy neighbor, at the cost of flexibility (fixed profiles, no oversubscription). Time-slicing (what we run) packs more logical GPUs but lets a heavy tenant degrade others.(tap/hover)
I'm your teacher. Ask me anything. Want to weigh MIG vs time-slicing for a specific multi-tenant scenario?
Slice one physical GPU into smaller isolated GPUs, or time-slice it. The tradeoff.
Today's win: you'll explain how MIG hardware-partitions one GPU into several isolated
instances for multi-tenant serving, how that differs from time-slicing, and when to reach for each, using
your cluster's actual setup as the example.
The picture: private stalls vs a shared kitchen on a timer
A 94 GB GPU is a big kitchen. If your dish only needs a third of it, the
rest is wasted. Two ways to share: build permanent walls into separate stalls each with their own
oven and counter (MIG, hard isolation), or let several cooks share the one kitchen on a timer
(time-slicing, flexible, but they can step on each other).
permanent walls + dedicated equipment
MIG: hardware partition, isolated SMs/HBM
sharing the kitchen on a timer
time-slicing: soft, oversubscribed, no isolation
fitting the dish to the stall
right-sizing by VRAM + KV headroom
1 · Right-sizing: don't waste a whole GPU on a small model
A model needs its weights plus KV headroom. A small
model on a 94 GB GPU leaves most of it idle. For multi-tenant or small-model serving, you want to
subdivide the GPU so several workloads share it.1
2 · MIG: hardware partitions
Multi-Instance GPU splits one physical GPU into up to 7 isolated
instances, each with its own dedicated SMs, HBM slice, and L2 (profiles like
1g.10gb, 3g.40gb, 7g.80gb). The isolation is in hardware:
one tenant literally cannot touch another's compute or memory: guaranteed performance, no noisy
neighbor.1
MIG carves dedicated slices with hardware walls; time-slicing lets tenants take turns on the
whole GPU. Isolation vs flexibility.
3 · MIG vs time-slicing: the tradeoff
MIG = hard, guaranteed isolation, but rigid (fixed profiles, can't oversubscribe).
Time-slicing = soft sharing: flexible and you can pack more logical GPUs than you have
physical ones, but there's no isolation; a heavy tenant starves the others (noisy
neighbor).2
4 · When to use which
MIG: multi-tenant with SLO isolation, or several small models that each fit a slice.
Time-slicing: bursty/dev workloads, or maximizing density when isolation isn't critical.
Whole GPU: a big model (like your 27B) that needs all the memory + bandwidth.
On YOUR cluster: you time-slice, not MIG real config
Your 4 H100s run time-slicing ×5 → 20 logical GPUs, with MIG disabled.
That's the flexible/oversubscribed choice: great for packing many workloads, but no hardware
isolation. A heavy tenant can degrade neighbors sharing the same physical GPU (a real noisy-neighbor
risk for your SLOs). If you needed guaranteed isolation per tenant, MIG would be the switch, at the cost
of that flexibility. Your big Qwen, though, wants a whole GPU regardless. · Your Lab →